Black Friday Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65pass65

Good News !!! D-PST-MN-A-24 Dell PowerStore Maintenance Achievement is now Stable and With Pass Result

Exams4sure Dumps

D-PST-MN-A-24 Practice Exam Questions and Answers

Dell PowerStore Maintenance Achievement

Last Update 1 day ago
Total Questions : 61

Dell PowerStore Maintenance Achievement is stable now with all latest exam questions are added 1 day ago. Incorporating D-PST-MN-A-24 practice exam questions into your study plan is more than just a preparation strategy.

D-PST-MN-A-24 exam questions often include scenarios and problem-solving exercises that mirror real-world challenges. Working through D-PST-MN-A-24 dumps allows you to practice pacing yourself, ensuring that you can complete all Dell PowerStore Maintenance Achievement practice test within the allotted time frame.

D-PST-MN-A-24 PDF

D-PST-MN-A-24 PDF (Printable)
$43.75
$124.99

D-PST-MN-A-24 Testing Engine

D-PST-MN-A-24 PDF (Printable)
$50.75
$144.99

D-PST-MN-A-24 PDF + Testing Engine

D-PST-MN-A-24 PDF (Printable)
$63.7
$181.99
Question # 1

A Storage Administrator needs to add drives to a base enclosure of a Dell EMC PowerStore 3000X system. The system currently contains 10 750-GB NVMe SCM drives.Which

drive configuration maximizes the base enclosure capacity?

Options:

A.  

13 750-GB NVMe SCM drives in slots 10-22

B.  

11 750-GB NVMe SCM drives in slots 10-20

C.  

13 15360-GB NVMe SSD drives in slots 10-22

D.  

11 15360-GB NVMe SSD drives in slots 10-20

Discussion 0
Question # 2

What is an alternative way to collect logs instead of using the Dell EMC PowerStore manager GUI?

Options:

A.  

Data Collect using Service Container

B.  

USB stick inserted into the system

C.  

Data Collect using vCenter

D.  

Discovery Utility

Discussion 0
Question # 3

Question # 3

Refer to the exhibit.

What is indicated when the circled LED on an expansion enclosure is illuminated amber?

Options:

A.  

Expansion enclosure power-on

B.  

Expansion enclosure faulted

C.  

SAS bus link down

D.  

SAS bus link up

Discussion 0
Question # 4

While on-site installing a Dell EMC PowerStore system, the node A and B embedded module fault LEDs are alternating blue and amber (blue for 3 seconds). What does this

indicate?

Options:

A.  

Nodes are in service mode

B.  

Nodes are in degraded mode

C.  

The system is not initialized

D.  

The system is booting

Discussion 0
Question # 5

When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?

Options:

A.  

svc_node restart

svc_rescue_state start

B.  

svc_node shutdown

svc_rescue_state clear

C.  

svc_rescue_state clear

svc_node reboot

D.  

svc_rescue_state normal

svc_node start

Discussion 0
Question # 6

In which step of the ICW can the configuration details be exported?

Options:

A.  

Support Assist

B.  

Cluster Configuration

C.  

Cluster Details

Discussion 0
Question # 7

While on-site troubleshooting a Dell EMC PowerStore system, the node B embedded module fault LED is blinking blue and amber alternating at one second intervals. What doesthis indicate?

Options:

A.  

Node is in service mode

B.  

System is not initialized

C.  

Node is booting

D.  

Node is in degraded mode

Discussion 0
Question # 8

A Storage Administrator notices a Critical alert present in Dell EMC PowerStore Manager relating to data integrity. What action within the alert details slide-out panel is helpful in

troubleshooting the problem?

Options:

A.  

Examine Notifications to obtain a list of corrective actions

B.  

Access the Repair Flow link to schedule a support engagement

C.  

Re-engage support through previous listed Related Events

D.  

Select the Gather Support Materials from Service and Support

Discussion 0
Question # 9

Through which network do external hosts connect to the cluster for data access?

Options:

A.  

Storage

B.  

Management

C.  

Service

D.  

Internal

Discussion 0
Question # 10

What is the result of setting a VLAN ID of 0 on a network when running ICW for Dell EMC PowerStore?

Options:

A.  

Default route is set

B.  

Network will pass tagged traffic

C.  

Network will pass untagged traffic

D.  

Static route is set

Discussion 0
Get D-PST-MN-A-24 dumps and pass your exam in 24 hours!

Free Exams Sample Questions