Winter Special Sale Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 2493360325

Good News !!! PR000041 PowerCenter Data Integration 9.x:Developer Specialist is now Stable and With Pass Result

PR000041 Practice Exam Questions and Answers

PowerCenter Data Integration 9.x:Developer Specialist

Last Update 9 hours ago
Total Questions : 70

PowerCenter Data Integration 9.x:Developer Specialist is stable now with all latest exam questions are added 9 hours ago. Incorporating PR000041 practice exam questions into your study plan is more than just a preparation strategy.

PR000041 exam questions often include scenarios and problem-solving exercises that mirror real-world challenges. Working through PR000041 dumps allows you to practice pacing yourself, ensuring that you can complete all PowerCenter Data Integration 9.x:Developer Specialist practice test within the allotted time frame.

PR000041 PDF

PR000041 PDF (Printable)
$48
$119.99

PR000041 Testing Engine

PR000041 PDF (Printable)
$56
$139.99

PR000041 PDF + Testing Engine

PR000041 PDF (Printable)
$70.8
$176.99
Question # 1

What does the function SETVARIABLE ($$Variable, value) do?

Options:

A.  

Assign the minimum value of the twoto $$Variable

B.  

Assign the maximum value of the two to $$Variable

C.  

Allows the assignment of a value to a parameter

D.  

Assign the value to $$Variable, unless the value is null

Discussion 0
Question # 2

Which port types are applicable to the Stored Procedure transformation?(Choose all that apply) Choose 3 answers

Options:

A.  

lnput

B.  

Output

C.  

Variable

D.  

Return

Discussion 0
Question # 3

What is a pipeline lookup transformation?

Options:

A.  

A lookup created using a pipeline which contains a target

B.  

A lookup cache split over pipelines of a partitioned mapping

C.  

A lookup associated with the Source Qualifier or an Application source such as JMS or SAP

D.  

A pipeline lookup does not exist

Discussion 0
Question # 4

Based upon the graphic below, which answer correctly discribes the outcome of this workflow's execution given the start method: (The workflow is valid)

• Workflows > Start Workflow

Question # 4

Options:

A.  

AII objects displayed will be executed

B.  

The Start task only will be executed

C.  

The Start task and the link will execute, while the session task will wait to execute

D.  

The Start task and link only will be execute

Discussion 0
Question # 5

Of the statements below, which best describes the underlying process taken when a user connects to a PowerCenter Repository Service for the first time? For the puposes of this question, the PowerCenter Developer is the only PowerCenter client application running, there are 2 nodes in the domain, node 1 is a gateway node and node 2 is a worker node. The PowerCenter Repository Service is running on the worker node.

Options:

A.  

The user connects directly and immediately to the Repository Service

B.  

The user connects to the service manager of the gateway node, and after authentication and authorization, is re- Assigned to the Repository Service

C.  

The user connects to the service manager of the worker node that is running the Repository Service, is then authenticated, authorized, and connected to the PowerCenter Repository Service

D.  

The user first connects to the PowerCenter Integration Service and then after authentication and authorization, is connected to the PowerCenter Repository Service

Discussion 0
Question # 6

What function would transform 12.99 to 13.0 and 15.44 to 15.4? (choose one)

Options:

A.  

ROUND

B.  

TRUNC

C.  

INSTR

D.  

CONCAT

Discussion 0
Question # 7

How does a single joiner transformation join data?

Options:

A.  

From 2 pipeline inputs

B.  

From 3 pipeline inputs

C.  

From n number of pipeline inputs assuming you have purchased the N-Joiner Option

D.  

none of the above

Discussion 0
Question # 8

When the Transformation Scope is set to All Input, which group of transformations listed below will always cause an upstream Transaction Control transformation to become ineffective? (choose one)

Options:

A.  

Filter, Joiner, Rank

B.  

Union, Filter, Aggregator

C.  

Rank, Lookup, Aggregator

D.  

Joiner, Rank, Sorter

Discussion 0
Question # 9

Assuming that the Master Pipeline has 5 fields, two of which are part of the join condition and that all fields are connected downstream to the next transformation, how many fields are in the index and data cache files?

Options:

A.  

5 fields are in the index cache and 3 are in the data cache

B.  

3 fields are in the index cache and 2 fields are in the data cache

C.  

2 fields are in the index cache and 3 fields are in the data cache

D.  

2 fields are in the index and 5 fields are in the data cache

Discussion 0
Question # 10

Referring to the Sequence Generator transformation, which statement is correct and true?

Options:

A.  

The NextVal column produces the next number in the sequence

B.  

The cycle check box on the properties tab turns on a feature that randomizes the numbers but still produces a unique set of numbers for the sequence

C.  

The default ending value for a PowerCenter 9.x Sequence Generator is 2,147,483,647

D.  

The Sequence Generator contains a single input port that represents the initial starting point of the sequence

Discussion 0
Get PR000041 dumps and pass your exam in 24 hours!

Free Exams Sample Questions